Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!
Exterior Claddings

Lots of Lath

By Albert Carrillo
December 1, 2015

Plaster has been applied for many centuries and in the earliest of times, was applied to a solid surface like a pyramid wall. But there is historical evidence that early man, using mud as a form of plaster, applied it to a framework of sticks and interwoven reeds. This stick and reeds was the first form of what we use today in our plaster environment, that binding framework known as lath.

Our modern forms of exterior lath are an intricate, sometimes artful, form of various configurations of metal. Some are welded into an engineered web, others stamped and expanded to create hexagonal shapes and yet others woven into octagonal nets, all designed to carry the weight of the cement cladding, stucco. Lath performs other functions as well. Yes it primarily holds the weight of the stucco cladding, maintaining the vertical plane, fighting gravity, but lath also works to gauge the thickness of the stucco. To some of us believers, the lath also acts as a sort of spandex for the building, keeping the framework from bulging and twisting all the while maintaining its sleek architectural form.

As with any construction product, technology ever moving forward has born new forms of this lath product utilizing new materials like spring steel and glass fibers, and through the years has been specially manufactured to perform in a variety of orientations. This month’s article will explore the various forms of lath used on the exterior walls and ceilings.

Expanded Metal Lath

This lath is probably one of the most recognized forms of modern lath. It is manufactured according to ASTM C847 standards. C847 requires a nominal thickness of 1/8-inch, a minimum width of 27 inches, a minimum length of 97 inches, and weights of 2.5 or 3.4 pounds-per-square-yard. It is formed by first manufacturing a sheet of G60 coated metal approximately 12 inches wide (ASTM A653). The sheet is then run through a series of cutters that stamp slits through the metal, and then the whole sheet is expanded, forming a diamond shape void. A self-furring version can be made by running the expanded sheet through another machine which adds dimples to keep the metal lath away from the substrate surface. Self-furring diamond mesh then has a 5/16 nominal thickness requirement. Expanded metal lath may be manufactured with a paper backing as well.

Non-furring expanded metal lath may be used for soffits or ceilings, over open frame. The use of this lath on soffits and ceilings does not require a water resistive barrier, nor should it be applied to sheathing. A minimum 3.4 pounds-per-square-foot lath should be used and it can be directly fastened to the framing members, a cross furring member, or tied to a suspended metal furring channel assembly.

For the wall assembly, expanded metal lath can be applied over open framing or a sheathed substrate surface. The building codes do require a WRB on all exterior wall assemblies. When metal lath is used over open framing the WRB may be given extra support between studs by line wire. This is a time proven process where wire is strung horizontally along a wall and fastened to the studs. The wire fills the void between studs and acts to keep the WRB and metal lath in plane during application of the stucco. Over a sheathed exterior wall assembly, a self-furring metal lath may be used. In this assembly the WRB is placed over the code approved sheathing material and the metal lath is fastened over that to each stud member. The edges of each sheet must overlap the adjacent sheet per ASTM C1063.

Because expanded metal lath is bendable, it can be used for other features and purposes. Metal lath can be formed over foam (not wood) features or architectural embellishments we know as pop-outs. Metal lath holds a bent shape and some contractors have taken to pre-bending metal lath to a given configuration and in large quantities, and then simply fasten them over the architectural shapes, rather than forming them in situ. This is a time proven cost saving procedure commonly used when a large amount of shapes are on a given elevation or building. It is also used to reinforce parapet locations. In the Southwest where parapets are a part of the architectural design, metal lath is bent to form the desired shape and then fastened to the parapet area. The rigidity of the lath helps to maintain some of the structural integrity of the stucco cladding keeping the shape while the stucco is applied.

Expanded metal lath also acts to reinforce smooth or worn surfaces or to provide a “bondable” surface for other products. On tilt-up wall surfaces, expandable metal lath may be fastened to the surface to reinforce the stucco adhesion providing a mechanical bond. It is also helpful when applied over a less than perfect surface, such as adobe, older stucco surfaces, or painted surfaces. Stucco is not really good at adhering to smooth or crumbly surfaces. But, it really sticks like gang busters to metal lath. For other claddings like EIFS, expanded metal lath can be fastened to aging stucco, smooth and/or painted surfaces, and act as a good substrate to adhere the EPS foam. Expanded metal lath has always been the go-to product for interior gypsum plastering.

Woven Wire

This form of metal lath is manufactured by weaving galvanized wire into a honeycomb type shape. The hexagonal shapes are sized to either 1- or 1½-inch. One-inch is manufactured specifically for one coat stucco assemblies and 1½-inch for three-coat. The lath may be manufactured in sheets but more commonly comes in rolls of 150 lineal feet. The minimum width of the sheet or roll is 36 inches and like expanded metal lath may be manufactured with a paper backing.

Woven wire is a popular lath throughout the Southwest region, for both commercial and residential structures. Most rolls have a stiffener wire running the length of the roll which, when the wire is stretched and fastened to the wall, acts as a sort of tensioner. This tension sort of hugs the building perimeter keeping the framing members in a plane which I believe, helps to minimize cracking from building movement.

It is important that the right gauge and dimension be used for each type of stucco cladding. 1-inch 20 gauge stucco netting may only be used for one-coat stucco applications. One may not use this netting for three-coat stucco, ever. Stucco netting manufactured in 1½-inch 17 gauge is used for all three-coat applications, (and in the Pacific Northwest, one-coat applications). This heavier gauge netting may also be used for alternative construction such as straw bale, ICFs, rammed earth and some adobe structures. None of these woven lath products should be used for soffits or ceilings and are not suggested for stand-alone uses on parapets or architectural shapes (see expanded metal lath on the first page of this column).

Welded wire

Welded wire lath is an engineered configuration of minimum .0625-inch galvanized wire electrically fused “welded” together to form a grid of parallel and cross wires. This form of lath cannot have any openings larger than 2-inch by 2-inch (ASTM C933). In the past, welded wire lath was only available in sheets however a new welded lath product available in rolls has recently been introduced. Like its expanded metal and woven brethren, welded wire is available with or without paper backing.

Welded wire lath is a heavier type of lath that is specifically manufactured to maintain a consistent furring from the substrate. Some versions have special horizontal slots in which to place the fasteners. This engineering of fastener locations helps to create a uniform furring level. The lath also has a bit more tensile strength than the other types.

Rib Metal Lath

This lath is manufactured with ribs running parallel to each other with a diamond shape lath between each rib (ASTM C847). This type of lath is manufactured with flat ribs or 3/8-inch ribs, is applied to ceilings and soffits and wall spans at 24 inches-on-center. The ribs provide for rigidity of the lath as it spans the rafters which are usually spaced 24 inches-on-center. In the stucco industry rib lath is more commonly used for ceilings and soffits than for walls. Rib lath comes without a paper backing but for stucco spray applications can be manufactured with paper strips attached along the mesh areas to inhibit blow-by. The rule of thumb with rib lath is to use the flat rib for spans up to 19 inches and 3/8-inch ribs for spans up to 24 inches.

Glass Fiber Lath

Specially treated glass fibers are woven into a configuration of squares and are used as lath for stucco. This type of lath is a relative newcomer to the stucco industry. It was developed as a lightweight corrosive resistant lath that is easy to hang. It also performs well in high salt areas like those along the coastline. ASTM does not publish a report on this lath and each manufacturer must have an ESR report.

The selection of which type of lath to use on a given project relies first on the desired specification requirements, and second on the preference of the contractor. It is common and acceptable to use two or three different types of lath on the same project. The most important consideration of lath selection is that the lath being used be manufactured to proper specifications. 

KEYWORDS: building codes construction EIFS

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Albert Carrillo is the Arizona manager for the Western Wall & Ceiling Contractors Association and Technical Services Information Bureau. He can be reached at (480) 829-9133.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • bar graph shows LEED v4/LEED v5/LEED v6 in various colors

    When Will LEED v4 / v4.1 and LEED v5 Expire?

    The latest version of the LEED rating system, LEED v5, is...
    Sustainability
    By: Daniel Overbey
  • Celebrating Women In AEC-2026

    Celebrating Women in The AEC Industry Part 1

    A round-up of women in the design, engineering and...
    Building Envelope
    By: Lindsay Lewis
  • KEE membrane application on a roof

    A Beginner’s Guide to Single-Ply Roofing Membranes

    While PVC and TPO appear extremely similar, the chemistry...
    Low-Slope Roofs
    By: Peter Gross
Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HITT Construction headquarters
    Sponsored byBuilding Composites® LLC

    Pushing the Envelope

  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

Popular Stories

Open vs. closed cell foam in an attic

Open-Cell vs. Closed-Cell Spray Foam

graphic shows white arrows pointing to the right on a light green background

A Breakdown of Air Leakage Testing in LEED v5 BD+C

graphic shows a building destoryed by tornados with information on the amount of torandos in 2026 in the US

Record-Breaking Tornado Activity in Illinois Signals New Challenges for Architects

Building Enclosure Newsletter

BE Poll

Events

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

April 28, 2026

Roof Design Considerations That Prevent Installation Failures and Change Orders

Credit: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU

On-Demand This course provides visual examples of actual field conditions. Some good, some not so good; along with design suggestions that can cut installation costs and reduce construction change orders. Upon completion of this course, you will have a better understanding of the requirements the roofing contractor must meet to provide the specified roofing system warranty, and long-term value to the owner.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products

Related Articles

  • EIFS

    Exploring the Beauty of Stucco and EIFS

    See More
  • EIFS Building

    Continuous Insulation Cladding

    See More
  • EIFS CI

    EIFS, the True Continuous Insulation (CI)

    See More

Related Products

See More Products
  • ecology.jpg

    Architecture and Systems Ecology: Thermodynamic Principles of Environmental Building Design, in three parts

  • 41G-JcZWT+L._SX342_SY445_.jpg

    The Architect's Studio Companion: Rules of Thumb for Preliminary Design, 7th Edition

  • 71lmKx8brKL._SY385_.jpg

    A Visual Dictionary of Architecture, 2nd Edition

See More Products

Events

View AllSubmit An Event
  • April 30, 2026

    Where Energy Efficiency Meets Life Safety: Polyiso CI and the Critical Role of NFPA 285

    Credits: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU On-Demand This presentation delivers a comprehensive look at the performance advantages of continuous insulation, with a special focus on polyisocyanurate (polyiso CI) solutions.
View AllSubmit An Event
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing