Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!

The Russo Report: Wind Uplift Solutions

By Michael Russo
April 8, 2009
There is still a common misconception in the design community that Factory Mutual (FM) I-90 represents winds of 90 mph. In fact, the standard requires the roof system to withstand 90 pounds per square foot (psf) of wind uplift tested pressure.

There is still a common misconception in the design community that Factory Mutual (FM) I-90 represents winds of 90 mph. In fact, the standard requires the roof system to withstand 90 pounds per square foot (psf) of wind uplift tested pressure.

There are actually many calculations that go into the wind design process-all based on the original ASCE-7 standard for building envelope pressures. Building location, height, ground roughness and other factors all enter into the wind uplift equation.

In general, designing for 90 psf is overkill except in high wind areas. However, I-90 is frequently rubber-stamped in up to 80 percent of roofing specifications where 75 or 60 psf would be adequate and more cost effective. Currently, for building design pressures up to and including 45 psf, using an FM safety factor of 2, Factory Mutual now requires the roof assembly to withstand the following tested differential ultimate pressures:
  • Field of Roof: 90 psf
  • Perimeter of Roof: 150 psf
  • Corner areas of Roof: 225 psf
For building design pressures up to 60 psf, using an FM safety factor of 2, Factory Mutual now requires the roof assembly to withstand the following tested differential ultimate pressures:
  • Field of Roof: 120 psf
  • Perimeter of Roof: 195 psf
  • Corner areas of Roof: 300 psf
In addition, roof assemblies over 90 psf are tested to these pressures on a 12-foot by 24-foot uplift testing table. The old method of simply increasing the roof-field fastener count by fixed percentages for perimeter and corner areas of adhered systems is no longer accepted for the FM field-of-roof ratings of 90 psf and higher.

As one can see from the charts above, the required uplift resistance at the corners of the roof is much higher than the field of the roof. This is because the roof edges were the determining factor in failures, according to FM’s and RICOWI’s research. However, there are other methods of strengthening the edges and corners of roof systems, such as using a “peel stop” on roofing membranes. (For more information on peel stops, visit www.spri.org.)

When these changes took place in 2006, only a handful of the multitude of fully adhered specifications were able to meet the new FM standards, and many roof system suppliers had to re-test.

One way to meet the new FM requirements and increase the “strength” of the roofing assembly is to specify a 1/2-inch pre-primed gypsum cover board directly fastened to the roof deck. In recent testing, a three-ply built-up roof (BUR) with 1.5 inches of loose laid polyiso insulation achieved an impressive FM rating of 315 psf - 15 psf higher than the elevated corner pressures required for an FM I-120 listing.

Similarly, a 45-mil, fleece-backed EPDM single-ply membrane fully adhered with hot asphalt tested at 285 psf. A number of membrane manufacturers have tested various types of gypsum cover boards with their adhered membranes and have achieved a variety of high uplift results.

Share This Story

Michael Russo is a contributing writer to Roofing Contractor. He can be reached at mikerusso1983@zoominternet.net. 

Recent Comments

These are actually very helpful tips. It is...

This is the most beneficial blog for all...

This blog is a great resource for anyone...

Thank you for sharing this important information. I...

This is a very interesting subject of the...

Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HITT Construction headquarters
    Sponsored byBuilding Composites® LLC

    Pushing the Envelope

  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

Popular Stories

graphic shows white arrows pointing to the right on a light green background

A Breakdown of Air Leakage Testing in LEED v5 BD+C

Open vs. closed cell foam in an attic

Open-Cell vs. Closed-Cell Spray Foam

skyscraper

NYC Tower Failure Offers Warning for Contractors

Building Enclosure Newsletter

BE Poll

Events

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

April 28, 2026

Roof Design Considerations That Prevent Installation Failures and Change Orders

Credit: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU

On-Demand This course provides visual examples of actual field conditions. Some good, some not so good; along with design suggestions that can cut installation costs and reduce construction change orders. Upon completion of this course, you will have a better understanding of the requirements the roofing contractor must meet to provide the specified roofing system warranty, and long-term value to the owner.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing