Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!

Technical Details: Waterproofing or Dampproofing, That Is the Question

By BNP Media Staff
July 14, 2011
The first question that an architect will have to answer is if waterproofing is required on the building that they are designing.

The first question that an architect will have to answer is if waterproofing is required on the building that they are designing. This can be a complex question and the answer could have significant ramifications over the life span of the structure. Economic and code requirements could also weigh heavily in the decision process. Waterproofing may be included for peace of mind, as this is the one component of the building that it may be best to caution on the side of err.

Once there is determination that waterproofing is required, the designer faces the equally daunting question of determining whether dampproofing or waterproofing is required and where they should be applied. In order to correctly decipher where to use waterproofing and dampproofing the designer should be familiar with these types of materials and the basic waterproofing design elements of each.

Dampproofing is a system designed merely to resist the flow of moisture in a gaseous state. It can only be used in below-grade walls that are not subjected to hydrostatic pressure. These types of systems resist the flow of water vapor through a building component. They are most commonly used to prevent or reduce migration of water by diffusion. The most common form of dampproofing material is bituminous (asphalt) coating, which is either solvent-based (cut-back asphalt) or emulsion. These coatings are applied in one or more applications with a brush, spray, or trowel. Reinforcements are rarely applied in these systems. If reinforcements are used they typically consist of woven jukes or cotton fabrics that are specially applied over substrate cracks or openings.

Waterproofing systems are designed to resist hydrostatic pressure that is extended by moisture in a liquid state. Waterproofing systems typically use reinforcement membranes that can be adhered to the substrate in a variety of application methods. Typical application methods include hot application with heated asphalt, cold applications with solvent based adhesives, torch applications or self adhered membrane sheets.

The decision to use waterproofing or dampproofing systems can be determined by three criteria. First, if hydrostatic pressure is present, a waterproofing system is required. A waterproofing system is also required for framed slab constructions. For retaining walls or slabs-on-grade the question is whether a slight leak risk is acceptable. If the answer is yes, then dampproofing may be considered. If the answer is no, then waterproofing is required.

There are two basic configurations of below-grade components that require dampproofing or waterproofing. The first is a “box” configuration that consists of a structural slab on top, foundation walls on the sides and a slab-on-ground at the bottom. The other type of configuration is an “L-shape” configuration, which consists of a foundation and a slab-on-ground with no structural slab.

The type of waterproofing treatment applied at these components is based on the three criteria that are identified above and the following three basic rules of waterproofing design:
  1. You must waterproof the structural slab because it will be subjected to hydrostatic pressure from surface runoff.
  2. If you waterproof the slab-on-ground, you must waterproof the foundation wall – particularly if there is a fluctuating water table.
  3. You must either dampproof or waterproof both the foundation wall and the slab-on-ground
In most cases, the designer will determine whether waterproofing or dampproofing is required and use a single method to waterproof the below-grade components. However, it is not uncommon for both waterproofing and dampproofing systems to be applied on the same structure’s below-grade components. There are six combinations of building components where each method can be used in unison:
  1. Waterproofed structural slab, plus dampproofed wall and slab-on-ground
  2. Waterproofed structural slabs, walls, and slab-on-ground
  3. Waterproofed structural slab and walls, plus dampproofed slab-on-ground
  4. Dampproofed foundation wall and slab-on-ground
  5. Waterproofed wall and slab-on-ground
  6. Waterproofed wall, dampproofed slab-on-ground

Share This Story

Recent Comments

These are actually very helpful tips. It is...

This is the most beneficial blog for all...

This blog is a great resource for anyone...

Thank you for sharing this important information. I...

This is a very interesting subject of the...

Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

  • A construction worker using DEXcell roof boards
    Sponsored byDEXcell Roof Boards

    The Hidden Strength of Low-Slope Roof Systems: Why Roof Cover Boards Matter

Popular Stories

construction industry workers in hard hats stand around a city scape

Construction Industry Revolts Over New CSI Licensing Plan

graph shows green, orange and red dot lines going up

LEED v5 and the Cost Impacts of ASHRAE Standard 90.1-2019

2 construction workers and a DEXcell panel

Designing Low-Slope Roofs for Resilience

Building Enclosure Newsletter

BE Poll

Events

June 17, 2025

Addressing Condensation in Low-Slope Roof Assemblies

Credits: 1 AIA LU/HSW; 0.1 ICC CEU; 1 IIBEC CEH; 0.1 IACET CEU

On Demand In modern roofing systems, vapor retarders and air barriers do more than just minimize air leakage—they’re essential to maximizing performance and longevity. This engaging course dives into the next generation of moisture control: permeable vapor retarders and air barriers. Discover how these cutting-edge technologies are transforming low-slope roofing assemblies by improving energy efficiency, managing moisture, and boosting wind uplift resistance.

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing