Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!

The Russo Report: Vegetative Standard Gets 'Green' Light

By Michael Russo
March 16, 2010
The American National Standards Institute (ANSI) recently approved a key fire design standard for vegetative roofs developed by SPRI in cooperation with Green Roofs for Healthy Cities (GRHC).

The American National Standards Institute (ANSI) recently approved a key fire design standard for vegetative roofs developed by SPRI in cooperation with Green Roofs for Healthy Cities (GRHC).

ANSI/SPRI VF-1 “External Fire Design Standard for Vegetative Roofs” was approved on Jan. 29 after a final round of revising and re-balloting earlier in the year. SPRI Technical Director Mike Ennis, who also chairs SPRI’s Codes & Standards Task force, worked for several years with task force members Dave Roodvoets and Kelly Luckett on the standard. This team also continues work on ANSI/SPRI RP-14, a wind standard for vegetative roofing systems.

At the same time, SPRI’s Sid Teachey is leading the development of a root penetration standard for vegetative roof systems. The second draft of GRHC-SPRI VR-1, “Procedure for Investigating Resistance to Root Penetration on Vegetative Roofs,” is currently being prepared for ANSI canvassing.

Because of the rapid growth of the green movement, it is critical that the roofing industry develop standards like these to guide contractors and specifiers in the design and installation of vegetative roofs.

The recently released ANSI/SPRI VF-1 standard includes fire-control designs to limit the spread of flame if a vegetative roof system were to catch fire. The standard uses barriers of non-vegetative zones to contain a potential fire.

The standard’s use is limited to roof slope designs up to 2 inches in 12 inches and specifies use of fire stop walls and fire break roof areas. Fire walls must be of non-combustible construction and extend above the roof surface a minimum of 36 inches (914 mm).

The fire break roof areas must consist of a Class A (per ASTM E108 or UL790) rated roof system that creates a minimum 6 feet (1.8 m) wide continuous border around the vegetative roof. Fire break roof areas must also be included where vegetative roof systems abut vertical surfaces, such as rooftop structures, equipment and roof penetrations.

Fire stops are also specified for spread of fire protection for large roof areas. Fire walls or fire breaks are used to partition large roof areas into sections not exceeding 15,625 square feet (1,450 m2), with each section having no unbroken linear dimension greater than 125 feet (39 m). Incorporating the border zones into expansion joints or roof area dividers are recommended wherever possible.

“This was truly an industry effort including manufacturers, green roofing professionals, testing organizations, contractors, design professionals and consultants,” said Mike Ennis, technical director for SPRI.

Share This Story

Michael Russo is a contributing writer to Roofing Contractor. He can be reached at mikerusso1983@zoominternet.net. 

Recent Comments

These are actually very helpful tips. It is...

This is the most beneficial blog for all...

This blog is a great resource for anyone...

Thank you for sharing this important information. I...

This is a very interesting subject of the...

Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

  • A construction worker using DEXcell roof boards
    Sponsored byDEXcell Roof Boards

    The Hidden Strength of Low-Slope Roof Systems: Why Roof Cover Boards Matter

Popular Stories

construction industry workers in hard hats stand around a city scape

Construction Industry Revolts Over New CSI Licensing Plan

graph shows green, orange and red dot lines going up

LEED v5 and the Cost Impacts of ASHRAE Standard 90.1-2019

2 construction workers and a DEXcell panel

Designing Low-Slope Roofs for Resilience

Building Enclosure Newsletter

BE Poll

Events

June 17, 2025

Addressing Condensation in Low-Slope Roof Assemblies

Credits: 1 AIA LU/HSW; 0.1 ICC CEU; 1 IIBEC CEH; 0.1 IACET CEU

On Demand In modern roofing systems, vapor retarders and air barriers do more than just minimize air leakage—they’re essential to maximizing performance and longevity. This engaging course dives into the next generation of moisture control: permeable vapor retarders and air barriers. Discover how these cutting-edge technologies are transforming low-slope roofing assemblies by improving energy efficiency, managing moisture, and boosting wind uplift resistance.

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing