Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!
Building Envelope

Noise Mitigation for Residential Sites Near Transit

By Ethan Casavant
Hub-on-Causeway-North-Station-Bret Osswald.jpg

The Hub on Causeway Boston, Mass. Acentech was brought on at the start of the design process to provide advice and recommendations on a variety of noise and vibration issues at the (1,500,000 SF) residential and mixed-use Hub on Causeway development in Boston, including sound isolation from both under- and above-ground transportation systems, and isolation from the adjoining TD Garden arena. Architect: Gensler. Photo courtesy of Bret Osswald Photography.

the-lucas-Raj-Das.jpg

The Lucas Boston, Mass. Acentech provided acoustics and noise control for The Lucas (a former church) in Boston, designed by Finegold Alexander. Proper sound isolation techniques were vital to ensuring the effectiveness of these glass walls against noise from a nearby highway. Architect: Finegold Alexander Architects. Photo courtesy of Raj Das Photography.

Hub-on-Causeway-North-Station-Bret Osswald.jpg
the-lucas-Raj-Das.jpg
May 19, 2023

When evaluating the prospective location for a multi-family residential project, there are many factors that should be considered. Chief among them is a factor that is often overlooked: potentially intrusive existing noise sources around the building site. Here in the greater Boston area, Acentech has consulted on several residential projects along major transit lines. Noise from the Mass Pike and other highways, the commuter and light rail system, and Boston’s Logan Airport bombard building façades with high levels of noise. Special consideration is needed to ensure that noise from these modes of transit is addressed appropriately. And while it’s true that robust façade constructions on residential buildings near high-traffic areas are often imperative for the comfort of residents, they can also result in significant additional costs to the project if overdesigned.

With any residential project site near road, rail, or airport noise sources, the construction of the building envelope is especially crucial to the design process. From an acoustic standpoint, the window construction is most critical in achieving the desired overall sound isolation performance of the envelope, since windows typically have lower sound isolation ratings than standard exterior walls. In many cases, a typical 1-inch insulated glazing unit is not sufficient to attenuate exterior transit noise to an acceptable level. Varying the thickness or number of the lites, upgrading to laminated glass, or increasing the airspace between lites all impact the overall sound isolation capabilities of the window assembly. Modifications to one or more of these elements of the window are often necessary to attenuate transit noise. On one hand, specifying windows that do not provide the necessary level of sound isolation may result in disturbed and angry residents; on the other hand, installing a window with an excessively high sound isolation rating has diminishing returns, and can add unnecessary expense to the project.

 

Evaluation Process and Establishing Noise Goals

Before any decisions can be made regarding the building envelope, an evaluation of the project site should occur. Acentech’s process for evaluating environmental noise at a project site typically involves deploying long-term sound level meters at critical locations near the planned future façade. These meters collect noise data over the course of several days and nights, both during the week and weekend. We use this data to quantify the potential impact from steady-state and transient noise sources, each of which needs to be addressed to satisfy different noise goals.

Steady-state noise comprises the consistent noise levels that occur for extended periods of time during a certain time window, such as HVAC noise or consistent vehicle traffic along a highway. By performing a weighted average of noise data collected over the course of a 24-hour period, a Day-Night sound level, or DNL, can be calculated to describe the consistent noise level of a site in a single number. In our experience, we have encountered calculated DNL as high as 81 dBA for residential projects, which translates to about the noise level of a blender or garbage disposal. 

Table 1 in Chapter 48 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) handbook establishes recommended interior noise levels for HVAC related background sound for several project types. As outlined in this table (shown below), a typical background noise goal for residential living spaces is 35 dBA, and 40 dBA for bathrooms, kitchens, and other supplementary spaces.1 Designing a building façade such that intrusive noise from traffic is at or below these levels results in steady-state traffic blending in with the background. While the noise goals established by ASHRAE are widely accepted for most residential projects, some specific projects may have other noise goals. One such example is residential projects that pursue funding from the Department of Housing and Urban Development (HUD), which requires that interior noise levels do not exceed 45 dBA DNL.2
 

Untitled-1.png

 

Transient noise sources are shorter and typically louder than steady-state noise; when present, they can often control the sound isolation requirements of the façade. These events are a major concern near railways, since noise from train horns or bells often exceed steady-state background noise. We have encountered residential projects that experience peak noise levels as high as 110 dBA from transient events.

However, designing a window assembly to attenuate transient noises to 35-40 dBA is often very challenging without the use of potentially complex window assemblies, and runs the risk of expensive over-design. In these cases where transient noise sources are well above the steady-state metrics, a slightly elevated noise goal for transient events is a more reasonable target. Studies conducted by the World Health Organization (WHO)3 in 1999 and 2009 suggest that intrusive noise levels as low as 42-45 dBA can cause residents to wake up earlier than intended. As such, an alternate noise goal of 45 dBA is often used for intrusive transient noise events, depending on the type, frequency, and time of day the event occurs, as well as the sensitivity of the project. This is generally in agreement with the ASHRAE table referenced above. In some cases, pursuing an interior noise goal of 50 dBA from transient sources is more reasonable.

 

Project Example

One example of a project where both steady-state and transient events were a factor is a residential building in Chelsea, MA, located near several transit noise sources. Route 1, a major highway, passes on an elevated roadway less than 200 feet away, and the Silver Line bus route passes directly adjacent to the site. Also adjacent to the site is the commuter rail, where trains must use their horn less than 50 feet from the project site. Since this project was pursuing HUD funding, interior steady-state noise levels could be no higher than 45 dBA DNL, and a 50 dBA noise goal for transient sources was established. The project site experienced very high steady-state and transient noise levels, resulting in the need for 40 dB of attenuation in order to achieve the required 45 dBA DNL, and 50 dB of attenuation was required to decrease transient noise to the 50 dBA goal. 

In order to achieve 50 dB of attenuation, a window with an exterior insulating glass unit and an interior storm window with an airspace of 4 inches was required. While this window construction was necessary to address noise from transient events, many areas of the building were not exposed to these noise sources. Consequently, installing such a robust window in all locations of the project was not acoustically necessary. Specifying a more moderate triple glazed unit achieved the steady-state noise requirement for less severely-impacted locations on the project, and resulted in significant cost savings potential.

 

Auralizations

While there are several numerical metrics used to quantify the sound isolation performance of various assemblies, it is often challenging to translate these numbers into average subjective experience. When determining the impact of different window types beyond achieving specified project DNL goals, acoustic simulations, otherwise known as auralizations, can be helpful for translating these numerical metrics or noise spectra into a more tangible experience. 

Using measured data from the project site and recorded traffic noise samples, we can program, playback, and manipulate in real time samples of how intrusive noise would sound to an average listener and provide auditory examples of how each window or adjustment to the building envelope could impact the resulting interior noise environment. These models are very helpful for architects, owners, and others involved with the project to hear and make informed decisions regarding critical acoustical design elements. As opposed to relying solely on numerical estimates of predicted intrusive noise, participants can experience and decide for themselves what level of noise is acceptable and appropriate for the environment they aim to create.

While auralizations are helpful to understand how the rumble of steady state noise may sound inside a residence, simulating intrusive noise from transient factors can be just as impactful. Train passbys combine the steady state noise of a large engine and the cars passing on often rough tracks with short and loud sounds of the train horn. Similarly, the roar of jet engines flying to or from Logan Airport can be difficult to describe in numbers alone. Without the right considerations, both these events can have a significant impact on the residents. While predicted interior noise spectra or overall noise levels are informative, modeling the relevant events with different window assembly options provides a more accessible understanding of the difference between the constructions, and acts as a useful point of reference for those making these critical building design decisions.

 

Conclusion

Transit systems can have a significant impact on many project types. Gathering the necessary information regarding these impacts can be invaluable towards making informed decisions. Accordingly, we recommend that developers and design teams consider the following:

  • Thoroughly evaluate steady-state and transient noise events on the project site, to understand what sources will be impacting the future building. 
  • Identify the appropriate interior noise goals, to establish the sound isolation requirements of the building façade. 
  • And finally, consider pursuing an auralization to inform final decisions regarding window construction and other acoustic factors. Hearing the difference and making an informed decision can help to prevent future complaints, as well as saving construction costs.
     

While it’s true there are no ‘one size fits all’ solutions to noise sources near residential or commercial developments, there are general recommendations (such as those listed above) that can help reduce unwanted noise and make spaces more enjoyable for occupants. If you are a developer or part of a design team, consider hiring an acoustical consultant or noise control engineer early in the planning stage. Not only will you understand your site constraints more fully, you may even avoid over-designing your façade and save on construction costs down the road.

Transit systems can have a significant impact on many project types. Gathering the necessary information regarding these impacts can be invaluable towards making informed decisions. Accordingly, we recommend that developers and design teams consider the following:

 

Citations

  1. American Society of Heating, Refrigerating and Air-Conditioning Engineers. 2011 ASHRAE Handbook Heating, Ventilating, and Air-Conditioning Applications. Atlanta, GA, ASHRAE, 2011
    (https://leeds.primo.exlibrisgroup.com/discovery/fulldisplay?docid=alma991007320599705181&vid=44LEE_INST:VU1)
  2. US Department of Housing and Urban Development. (2023). Day/night noise level electronic assessment tool. Day/Night Noise Level Electronic Assessment Tool.
    https://www.hudexchange.info/programs/environmental-review/daynight-noise-level-electronic-assessment-tool/
  3. World Health Organization, Regional Office for Europe. Environmental Noise Guidelines for the European Region. Copenhagen, World Health Organization, 2018 (https://www.who.int/europe/publications/i/item/9789289053563)

 

KEYWORDS: acoustics ASHRAE multi-family buildings residential building STC (sound transmission class)

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Ethan Casavant is a member of Acentech’s Architectural Acoustics group. He consults on various projects involving residential, commercial, higher education, K-12, healthcare, and lab facilities. His areas of concentration include environmental and HUD-related noise evaluations, room shaping, sound isolation, and mechanical systems noise and vibration control. He can be reached at ecasavant@acentech.com

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • bar graph shows LEED v4/LEED v5/LEED v6 in various colors

    When Will LEED v4 / v4.1 and LEED v5 Expire?

    The latest version of the LEED rating system, LEED v5, is...
    Sustainability
    By: Daniel Overbey
  • Celebrating Women In AEC-2026

    Celebrating Women in The AEC Industry Part 1

    A round-up of women in the design, engineering and...
    Sustainability
    By: Lindsay Lewis
  • KEE membrane application on a roof

    A Beginner’s Guide to Single-Ply Roofing Membranes

    While PVC and TPO appear extremely similar, the chemistry...
    Low-Slope Roofs
    By: Peter Gross
Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HITT Construction headquarters
    Sponsored byBuilding Composites® LLC

    Pushing the Envelope

  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

Popular Stories

Open vs. closed cell foam in an attic

Open-Cell vs. Closed-Cell Spray Foam

graphic shows white arrows pointing to the right on a light green background

A Breakdown of Air Leakage Testing in LEED v5 BD+C

graphic shows a building destoryed by tornados with information on the amount of torandos in 2026 in the US

Record-Breaking Tornado Activity in Illinois Signals New Challenges for Architects

Building Enclosure Newsletter

BE Poll

Events

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

April 28, 2026

Roof Design Considerations That Prevent Installation Failures and Change Orders

Credit: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU

On-Demand This course provides visual examples of actual field conditions. Some good, some not so good; along with design suggestions that can cut installation costs and reduce construction change orders. Upon completion of this course, you will have a better understanding of the requirements the roofing contractor must meet to provide the specified roofing system warranty, and long-term value to the owner.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products

Related Articles

  • FiberFill inside a wall

    Hempitecture Introduces a New Bio-Based Blowable Insulation for Residential Market

    See More
  • Content Is King: Is The Tipping Point for Residential Solar Closer Than We Think?

    See More
  • Breaking News

    AIA Releases Updated Contracts for Multi-Family Residential

    See More

Related Products

See More Products
  • buildings.jpg

    Mechanical and Electrical Equipment for Buildings, 13th Edition

  • 41G-JcZWT+L._SX342_SY445_.jpg

    The Architect's Studio Companion: Rules of Thumb for Preliminary Design, 7th Edition

  • net zero.jpg

    Net Zero Energy Design: A Guide for Commercial Architecture

See More Products

Events

View AllSubmit An Event
  • September 30, 2025

    Loss Mitigation Through Building Design

    Credits: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEUOn-Demand Through this course, learn about how specifying the roof edge is the single most cost-effective enhancement for wind uplift on a commercial roof and how you can help mitigate risk and protect lives through design.
  • July 21, 2026

    Designing for Quiet

    Credit: Credit 1 AIA LU/HSW pending; 1 IIBEC CEH; 0.1 ICC CEUThis course examines the most common acoustic challenges encountered in commercial-to-residential adaptive reuse projects and pairs each challenge with practical, design-based solutions. With an emphasis on sound transmission through walls and the limitations of Sound Transmission Class (STC) ratings, the course explores how flanking paths, structure-borne noise, HVAC systems, and detailing influence real-world acoustic performance. 
View AllSubmit An Event
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing