Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!
Project ProfilesSustainabilityWall Systems

McKelvey Hall at WashU Aligns with LEED and WELL Criteria

MO-WashU-McKelvey_PaúlRivera14_Apogee-Tubelite-Linetec.jpg

Photo by Paúl Rivera; courtesy of Tubelite Inc. and Apogee Enterprises, Inc.

September 5, 2022

Part of the largest capital project in Washington University's (WashU's) 125-year history, James M. McKelvey, Sr. Hall completes the final stage for the East End Transformation of Danforth Campus in St. Louis, Missouri. Sustainability and occupant well-being were essential objectives for the university.
 
To meet the project's numerous design goals and performance requirements, Tubelite Inc. and its representative, Doug Urich of ARCHON Fenestration Technologies worked closely with the design and building team. In addition to Tubelite, WashU's 86,500-square-foot McKelvey Hall project was supported with products and services from Wausau Window and Wall Systems, Viracon and Linetec.
 
Going for Gold
Perkins Eastman led the design of McKelvey Hall working closely with St. Louis-based Patterhn Ives as associate architect and WashU's Facilities Planning & Management. As the new home of the Department of Computer Science & Engineering, McKelvey Hall was designed to be 30% more efficient than a standard building. It is on track to achieve LEED® v4 Gold certification or higher through the U.S. Green Building Council.
 
The project team followed an integrated design process incorporating the principles of sustainable design with attention to energy efficiency, low-impact materials, reuse and recycling, quality and durability, and health and wellness. Every material selected for McKelvey Hall was screened against a multitude of variables, including LEED v4 requirements, Red List chemicals, healthcare-level standards outlined in the Healthier Hospitals Initiative and the WELL Building Standard™.
 
Looking Forward
McKelvey Hall's three-story structure respects WashU's architectural legacy by incorporating Missouri red granite and limestone masonry. Bridging the Collegiate Gothic style reminiscent of European universities and carrying the campus forward, the modern aluminum-framed glass façade serves as a dramatic window into the school's innovative, computational research and connects students with views of the surrounding campus.
 
To create the McKelvey Hall's transparent and dramatic elements, ARCHON provided Tubelite's Therml=Block™ 900RW Series Thermal Window Wall, and 400T Series Thermal Curtainwall and wide stile doors for the hall's entrance area. Wausau supplied additional unitized curtainwall glazed with Viracon's VNE24-63 glass.
 
Ensuring WashU's and the architectural team's expectations were met, a full-size, finished mock-up was prepared for approval prior to installation.

McKelvey Hall at WashU - Paúl Rivera

Energy-Efficient Elements
Helping achieve the building's energy-efficiency criteria, Tubelite's and Wausau's aluminum framing members were thermally broken. Tubelite's 900RW single and dual thermal break options allow architects and specifiers to select appropriate thermal performance levels to meet their projects' requirements.
 
"Designed for clerestory and ribbon window applications in low- to mid-rise commercial buildings, Tubelite's 900RW window wall saves installation time and labor, while meeting model energy codes and supporting LEED certification," said Tubelite's senior manager of product strategy, Brian Tobias, LEED AP. "Tubelite's Therml=Block products provide superior energy and condensation resistance performance using multiple thermal barriers, while providing structural integrity and aesthetic flexibility."
 
Tubelite's products are tested per the Fenestration and Glazing Industry Alliance's AAMA standards for air, water, structural and condensation resistance. They also are tested and modeled for thermal transmittance per the National Fenestration Rating Council's procedures.
 
"Thorough testing by an independent laboratory ensures the 400T is the highest quality curtainwall framing product the industry has to offer," Tobias added. "Our dependable entrance systems also support smooth, reliable operation in moderate to heavy use applications, such as university buildings. The strength and flexibility of our steel tie-rod construction allow installation professionals to easily modify, disassemble or resize them at the jobsite, helping complete projects more quickly."
 
Natural Light and Shading
Further enhancing performance and keeping occupants comfortable, Viracon's high-performance ultra-clear glass was paired with Wausau's vertical and horizontal sun shades plus custom shadowboxes. The exterior shading devices were engineered as integral components with the curtainwall, as were the interior 24-inch-deep light shelves that maximize daylight more deeply into the facility's interior.
 
"With attention to solar orientation and shading, ample natural light, high-performance façade design, and energy efficiency, the building promotes student productivity and well-being campus-wide," noted Perkins Eastman.
 
Environmentally Responsible Finishes
Enhancing both the building's performance and appearance, Linetec provided the thermal improvement and finishing for all of Tubelite's and Wausau's aluminum framing, as well as finishing the shading systems and parapet trim. "Amazing Gray" and "Noble Gray" colors were selected and applied using high-performance 70% PVDF resin-based architectural coatings.
 
To safely remove the VOCs in the liquid paints' solvents, Linetec uses a 100% air capture system and regenerative thermal oxidizer. By managing this in its quality-controlled facility, there is no adverse environmental impact either at Linetec or on the jobsite.
 
For McKelvey Hall, Linetec applied the 70% PVDF resin-based coating to meet AAMA 2605 specification, the most stringent in the industry. Following this standard, these architectural coatings are proven to withstand 4,000 hours of accelerated testing for humidity and salt spray, and resist chalking, gloss loss and chemicals. They also exhibit outstanding color retention and UV-resistance, contributing to university buildings' cost-effective maintenance.
 
At the end of their long lifespan on the building, the finished aluminum framing systems can be recycled. Linetec's environmentally responsible finishing supports LEED, WELL and other sustainable project goals.
 
Collaboration and Connection
Along with meeting WashU's numerous sustainability and well-being requirements, McKelvey Hall fulfills the school's intellectual vision and academic plan. Named in honor of the dean of the School of Engineering & Applied Science, James M. McKelvey Sr., the new facility was envisioned as a space for interdisciplinary collaboration and high-impact research.
 
 Promoting openness and creating connections, the hall physically links the university's schools and buildings, while fostering engagement between teachers and students. The new building includes 19,000 square feet of research space, a café, the Judith Hood McKelvey Commons, faculty and departmental offices, plus shell space for future classrooms and research.
 
Recognized Success
McKelvey Hall was one of six new high-performance buildings totaling 713,000 square feet across 18 acres that realized WashU's Danforth Campus East End Transformation. The coordinated campus-wide effort earned a 2021 St. Louis Business Journal: Building STL Award, a 2020 Keystone Award from the American General Contractors (AGC) Missouri chapter and a 2020 national Honor Award for Excellence in Planning from The Society for College and University Planners (SCUP).
 
The sweeping East End planning, design and construction project also converted nearly six acres of surface parking into green space, furthering the university's commitment to sustainability. A greater connection between the city and community is achieved with a reimagined entrance to campus across the street from Forest Park, long considered one of the best urban public parks in the nation.
 
Intentional Transformation
"Not only is the East End a breathtaking and sustainable extension of the Danforth Campus; its intentional design, architecture and proximity to Forest Park signify our openness and accessibility to the wider community as well as our commitment to collaboration across departments and disciplines," said WashU Chancellor Andrew D. Martin.
 
He continued, "With careful attention to these details, this transformation allows us to further our mission to pursue distinction in education and research and to be an even stronger neighbor and partner as we open our doors to the St. Louis region even wider."
 
"This project was truly a unique opportunity to honor our physical heritage and lay the foundation for our future," added Henry S. Webber, the university's executive vice chancellor and chief administrative officer. "These world-class facilities will support world-class teaching and research and the everyday activities of our faculty, students, staff and guests for many years. I want to commend the project team at the university, our contractors and our design teams on a job very well done."
KEYWORDS: daylighting fenestration glass glazing PVDF (Polyvinylidene Difluoride) sustainable design

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • bar graph shows LEED v4/LEED v5/LEED v6 in various colors

    When Will LEED v4 / v4.1 and LEED v5 Expire?

    The latest version of the LEED rating system, LEED v5, is...
    Sustainability
    By: Daniel Overbey
  • Celebrating Women In AEC-2026

    Celebrating Women in The AEC Industry Part 1

    A round-up of women in the design, engineering and...
    Sustainability
    By: Lindsay Lewis
  • KEE membrane application on a roof

    A Beginner’s Guide to Single-Ply Roofing Membranes

    While PVC and TPO appear extremely similar, the chemistry...
    Low-Slope Roofs
    By: Peter Gross
Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HITT Construction headquarters
    Sponsored byBuilding Composites® LLC

    Pushing the Envelope

  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

Popular Stories

Open vs. closed cell foam in an attic

Open-Cell vs. Closed-Cell Spray Foam

graphic shows white arrows pointing to the right on a light green background

A Breakdown of Air Leakage Testing in LEED v5 BD+C

graphic shows a building destoryed by tornados with information on the amount of torandos in 2026 in the US

Record-Breaking Tornado Activity in Illinois Signals New Challenges for Architects

Building Enclosure Newsletter

BE Poll

Events

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

April 28, 2026

Roof Design Considerations That Prevent Installation Failures and Change Orders

Credit: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU

On-Demand This course provides visual examples of actual field conditions. Some good, some not so good; along with design suggestions that can cut installation costs and reduce construction change orders. Upon completion of this course, you will have a better understanding of the requirements the roofing contractor must meet to provide the specified roofing system warranty, and long-term value to the owner.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products

Related Articles

  • GAF Materials Corporation Aligns with Ply Gem to Elevate Exterior Home Design

    See More
  • usgbc

    USGBC and IWBI Release Streamlined Certification Pathway for LEED and WELL

    See More
  • Wagoner Hall Exterior.jpg

    New Mixed Grade, Living/Learning Wagoner Hall at Augustana University

    See More

Related Products

See More Products
  • studentguidebook.jpg

    Integrating Building Performance with Design: An Architecture Student’s Guidebook

  • business.png

    How to Succeed With Your Own Construction Business

See More Products

Events

View AllSubmit An Event
  • December 17, 2025

    Future-Ready Design: Navigating the LEED v5 Rating System

    Credits: 1 AIA LU/HSW; 1 ZNCD Credit; 0.1 ICC CEUOn-Demand This session provides an overview of the LEED v5 BD+C: New Construction rating system, including its structure, goals, and credits. An emphasis will be placed on critical changes in the rating system since LEED v4/v4.1.
View AllSubmit An Event
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing