Building Enclosure logo
search
cart
facebook twitter linkedin youtube instagram Spotify Podcasts Apple Podcasts Spotify Podcasts Apple Podcasts
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Building Enclosure logo
  • NEWS
    • Breaking News
  • SECTIONS
    • Columns
    • Project Profiles
    • Trade Shows
    • Sponsor Insights
  • SYSTEM DESIGNS
    • Low-Slope Roofs
    • Pitched Roofs
    • Metal Roofing Materials
    • Waterproofing
    • Sustainability
    • Insulation
    • Exterior Claddings
    • Wall Systems
    • Building Envelope
  • BLOG
    • The BE Blog
  • MEDIA
    • Podcasts
    • Webinars
    • Quiz
    • Videos
    • Polls
    • Interactive Spotlights
    • Newsletter
    • Photo Galleries
  • DIRECTORIES
    • Directory: Blue Book
    • Directory: Roofing Resource
  • PRODUCTS
  • TECHNICAL
    • Codes
      • Waterproofing
      • Roofing
    • Details
      • Waterproofing
      • Roofing
  • CONTINUING ED
  • ABOUT
    • Advertise
      • Editorial Calendar
    • Contact
    • eMag Archive Issues
  • SIGN UP!
Building EnvelopeWall Systems

Benefits of Translucent Polycarbonate Window and Wall Systems

By Victoria Scanlon
EXTECH_AZ-Fieldhouse_MJohnson-WinquistPhotog04448.jpg

The Fieldhouse, designed by Orcutt Winslow and constructed by Fleming West, features EXTECH’s LIGHTWALL 3440 interlocking wall system installed by Systems Contractors Inc. The resulting translucent building envelope maximizes natural lighting during the day and creates a soft glowing appearance when lit from the inside at night. High light levels, solar control and durability were equally important attributes for the project’s energy efficiency goals. Photo by Matt Johnson, Winquist Photography; courtesy of EXTECH.

EXTECH_WI-BeloitPowerhouse_Ext434_003-TomHarris_courtesyStudioGang.jpg

Beloit College transformed a decommissioned coal-burning power station located along Wisconsin’s Rock River into a new, energy-efficient field house focused on student recreation and wellness. Now known as the Powerhouse, the $38 million renovated building is targeting LEED Silver certification through the U.S. Green Building Council. Photo by Tom Harris, courtesy of Studio Gang and EXTECH.

EXTECH_AZ-Fieldhouse_MJohnson-WinquistPhotog04448.jpg
EXTECH_WI-BeloitPowerhouse_Ext434_003-TomHarris_courtesyStudioGang.jpg
March 7, 2022

Global energy consumption will increase through 2050, according to the U.S. Energy Information Administration (EIA). Analyzing 5.9 million commercial buildings in the U.S., EIA found electricity represents the largest energy source and is used in 95 percent of buildings. More than three-fourths (78 percent) of commercial buildings are cooled using electricity. For space heating, natural gas (44 percent) or electricity (43 percent) are the major energy sources used.

Energy-efficient building envelopes assist in reducing commercial buildings’ consumption and associated emissions. High-performance, translucent cellular polycarbonate window and wall systems contribute to achieving buildings’ energy-efficiency goals. This in turn helps owners save on utility costs and add value by improving comfort, wellbeing and satisfaction for their tenants and occupants.

EIA’s most recent data reports that energy-efficient, multi-paned windows are featured in 60 percent of U.S. buildings, which account for 75 percent of commercial floorspace. This presents a significant opportunity to improve existing buildings and to construct new buildings with energy-efficient daylight openings, including polycarbonate glazing and wall systems.

 

Defining Polycarbonate Performance

Used in Europe for more than 50 years, cellular polycarbonate glazing (CPG) panels offer a translucent, lightweight, shatter-resistant alternative to clear glass. Unlike older glazing technologies, like Fiberglass Reinforced Plastic (FRP), commercial windows and wall systems with CPG panels provide a modern aesthetic with high performance and long lifespans.

Polycarbonate is 250 times more impact resistant than an equivalent thickness of annealed glass and 30 times more than that of non-modified acrylic. Used in exterior wall and window systems, CPG systems’ high impact resistance helps protect against vandalism and storm damage. Further exemplifying its resilience, polycarbonate will not support its own combustion. This means that when the source of heat or ignition is removed, polycarbonate will cease to combust.

Compared IGUs and other heavy glazing systems, lightweight CPG panels require less material for structural supports, less fuel for transportation and less labor. A 25 mm (1-inch) thick piece of polycarbonate glazing weighs approximately 0.65 lbs./ft2 compared to 6.25 lbs./ft2 for an IGU of the same thickness.

Because CPG material is formed through an extrusion process, CPG panels also can be provided at any length, as limited by shipping and handling. When installation is more efficient, downtime is minimized, allowing building owners and occupants to be more efficient and productive.

 

Evaluating Energy Efficiency

The insulating and thermal performance of CPG systems keep the unwanted heat outside in warmer climates and the cold outside in cooler climates. Because window and wall systems are constantly exposed to the sun, CPG panels are co-extruded with a layer to resist ultraviolet (UV) radiation and eliminate yellowing. The UV protection repels almost 99 percent of harmful UV rays.

When evaluating CPG window and wall systems’ thermal performance, U-value is used. U-value measures the rate of heat transfer and a lower number indicates better performance. On average, a U-value of 0.26 can be expected for a CPG system with a thickness of 25 mm (1-inch). In contrast, a U-factor of 0.48 would be typical of a double-pane, insulated glass unit (IGU) of the same thickness.

Solar heat gain refers to the increase in thermal energy of a space as it absorbs incident solar radiation. The solar heat gain coefficient (SHGC) is a ratio of transmitted solar radiation to incident solar radiation in a daylighting assembly, expressed as a number between 0.0 and 1.0.

A lower SHGC indicates less transmission of solar heat, and usually are required in warmer climates to help reduce cooling loads. Conversely, a higher SHGC will help bring in solar heat in cooler climates. There is no distinction between glazing materials; a wall system with polycarbonate glazing would need to meet the same requirements as one using IGUs.

 

Framing for Thermal Performance

Aluminum framing is the industry standard for most commercial buildings’ window and wall systems, including those featuring CPG panels. Supporting energy-efficiency goals, the interior and exterior surface of the metal framing can be separated and insulated to minimize heat transfer. This is known as thermally “breaking” the frame.

Even with a thermally broken frame, temperature fluctuations also can cause the metal to expand and contract. Deep glazing pockets and low-friction gaskets allow for thermal movement. Pressure plates also provide consistent pressure on the gaskets without over-tightening that might restrict the panels within the window or wall system’s frame.

Multiwall CPG systems often use a tongue-and-groove profile. Joints, which have no battens of any kind, create a visually continuous wall. Some panel configurations allow the insertion of reinforcing bars that extend the length of the panel. These bars increase the panel’s spanning capability.

 

Designing for Daylight and Diffusion

Light transmittance (LT) is an optical property that describes the percentage of incident visible light transmitted through the glazing material. Daylighting window and wall assemblies that utilize older technologies like FRP often have an LT range as low as 12-20 percent With light transmissions this low, substantially more FRP material is required to maintain the same light levels as systems with a higher LT. The addition of fiberglass infill insulation to these systems can further reduce LT.

Translucent CPG window and wall systems, or multi-pane IGUs, have an LT range of approximately 45-70 percent. Compared to FRP, these materials provide a higher LT per square foot, improving the amount of daylight entering the structure, while reducing overall system costs. As with all project designs, there are trade-offs to consider with light transmission and thermal insulation. A translucent CPG wall system provides an optimal balance between the insulating value and the benefits of daylighting.

Daylighting in commercial buildings also decreases the demand on electric lighting, which reduces the associated energy costs, emissions output and resource consumption. For building owners looking inside their properties for energy-saving opportunities, the EIA’s data indicates more investment in LED lighting upgrades, as standard fluorescent lighting is still used in 68 percent of U.S. commercial buildings. Regardless of their source, the CPG panels soften the electrically illuminated interiors to a subtle glow, reducing light pollution outside.

During the day, the sun’s natural light is diffused as it passes through the translucent CPG panels into the building. Most often CPG systems are specified with an opal color glazing, which delivers moderate to high diffusion for evenly distributed light, but also may be specified with a clear glazing for low diffusion and high light transmission.

Choosing the optimal amount of light diffusion can be critical to the building occupants’ comfort and concentration. Too much light can result in “hot spots” with reflections on computer screens. Too little light can lead to poor comprehension and inaccuracies. Both extremes can cause eyestrain and headaches.

 

Enhancing the Envelope

Along with meeting a building’s energy-efficiency requirements, CPG window and wall systems also offer complementary, sustainable benefits to owners and occupants.

Like diffused daylight, adequate ventilation and access to fresh air also contributes to occupant comfort. Long-spanning and multiwall CPG systems can be paired with operable vents. As seasons and climates permit, these functional openings provide natural, passive ventilation and increased air exchange without relying on electric-powered HVAC systems.

Supporting material transparency and reduced waste, the window and wall systems’ CPG panels and the aluminum framing can be specified with recycled content. Minimal cleaning and maintenance is needed during the systems’ long lifespan. If necessary, the CPG tongue-and-groove assembly usually makes simple and quick work of repairs or replacements. At the end of its use on a building envelope, the panels and framing are 100 percent recyclable.

Numerous research studies have shown when commercial buildings are designed, constructed and operated to meet energy-efficiency and environmental goals, they contribute to improved productivity, increased job satisfaction and fewer sick days for occupants; lower vacancy rates, higher lease rates, and decreased operational, human resource, maintenance and utility costs for owners.

For educational facilities, green building and daylighting studies also have demonstrated a correlation with increased focus and academic achievement, as well as reduced absenteeism among both students and staff. In schools designed with sustainable strategies, teachers also report high job satisfaction. When people like coming to the places where they work, learn and play, their happiness and health also benefits students, co-workers, their families and their larger community.

KEYWORDS: building envelope building performance daylighting energy efficiency walls windows

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

 

Extech victoriascanlon

Victoria Scanlon is the marketing manager at EXTECH/Exterior Technologies, Inc., where she leads the company’s communications. Headquartered in Pittsburgh, EXTECH manufactures and designs wall, window, skylight, canopy and custom façade systems. Scanlon is a graduate of California University of Pennsylvania. She can be reached at info@extechinc.com or 800-500-8083.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • bar graph shows LEED v4/LEED v5/LEED v6 in various colors

    When Will LEED v4 / v4.1 and LEED v5 Expire?

    The latest version of the LEED rating system, LEED v5, is...
    Sustainability
    By: Daniel Overbey
  • Celebrating Women In AEC-2026

    Celebrating Women in The AEC Industry Part 1

    A round-up of women in the design, engineering and...
    Sustainability
    By: Lindsay Lewis
  • KEE membrane application on a roof

    A Beginner’s Guide to Single-Ply Roofing Membranes

    While PVC and TPO appear extremely similar, the chemistry...
    Low-Slope Roofs
    By: Peter Gross
Manage My Account
  • Sign up for the Newsletter
  • Online Registration
  • Manage My Preferences
  • Registration Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the Building Enclosure audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of Building Enclosure or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • HITT Construction headquarters
    Sponsored byBuilding Composites® LLC

    Pushing the Envelope

  • 2 construction workers and a DEXcell panel
    Sponsored byDEXcell Roof Boards

    Designing Low-Slope Roofs for Resilience

  • Bell Bank headquarters in Fargo, North Dakota
    Sponsored bySto Corp.

    Drained and Back-Ventilated Rainscreens vs Pressurized-Equalized Rainscreens

Popular Stories

Open vs. closed cell foam in an attic

Open-Cell vs. Closed-Cell Spray Foam

graphic shows white arrows pointing to the right on a light green background

A Breakdown of Air Leakage Testing in LEED v5 BD+C

graphic shows a building destoryed by tornados with information on the amount of torandos in 2026 in the US

Record-Breaking Tornado Activity in Illinois Signals New Challenges for Architects

Building Enclosure Newsletter

BE Poll

Events

April 9, 2026

Strategies for High-Performance Below-Grade Waterproofing

Credits: 1 AIA LU/HSW ; 1 IIBEC CEH; 0.1 IACET CEU

On-Demand Designing a high-performance building enclosure requires more than just surface-level protection; it demands a rigorous, performance-based mastery of below-grade water and gas mitigation. This discussion will provide an expert-level analysis of below-grade waterproofing within the comprehensive framework of the high-performance building enclosure.

April 28, 2026

Roof Design Considerations That Prevent Installation Failures and Change Orders

Credit: 1 AIA LU/HSW; 1 IIBEC CEH; 0.1 ICC CEU

On-Demand This course provides visual examples of actual field conditions. Some good, some not so good; along with design suggestions that can cut installation costs and reduce construction change orders. Upon completion of this course, you will have a better understanding of the requirements the roofing contractor must meet to provide the specified roofing system warranty, and long-term value to the owner.

View All Submit An Event

Products

Plaster and Drywall Assemblies Manual

Plaster and Drywall Assemblies Manual

This is a comprehensive manual that goes beyond codes and standards, providing expert guidance in design, detailing, material selection and troubleshooting for plaster and drywall.

See More Products

Related Articles

  • Front View_Disney Cleo Parking Structure by Kingspan Light + Air.jpg

    A "Garden" of Translucent Polycarbonate Canopies at Disneyland Resort

    See More
  • YKK-AP

    Window Wall Systems

    See More
  • Wausau_WISafetyCouncil_Flag.jpg

    Wausau Window and Wall Systems Honored with Wisconsin Corporate Safety Award

    See More

Related Products

See More Products
  • 007145828X.jpeg

    Manual of Low-Slope Roof Systems Fourth Edition

  • ecology.jpg

    Architecture and Systems Ecology: Thermodynamic Principles of Environmental Building Design, in three parts

  • 0470872616.jpg

    Sustainable Renovation: Strategies for Commercial Building Systems and Envelope

See More Products
×

Enhance your expertise with unparalleled insights.

Join thousands of building professionals today. Shouldn’t you know what they know?

SUBSCRIBE TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing